ToolVox® X3
Administrator Guide
Important Safety Points
ITWLinxsurgeprotectorsandtheconnectedequipmentmustbeindoorsinadrylocationandin
thesamebuilding.Althoughyourprotectorisdurable,itsinternalcomponentsarenotisolatedfrom
theenvironment.Donotinstallanyproductnearanyheat-emittingappliances,suchasaradiatoror
heatregister.Donotinstallthisproductwhereexcessivemoistureispresent.
*ATTENTION*
To ensure proper protection, the SurgeGate module MUST BE CONNECTED TO EARTH
GROUND. There cannot be any exceptions. A minimum #14 green insulated copper wire,
with a ring terminal at each end, should be used. Route the wire as directly as possible. Do
not make any other connections to the ground terminal of the module.