GU-144-Epage 5 of 17
IA500
Administrator Guide
4 Wiring Diagram
IA500 SERIES PCB
RELAY
OUT
RNG
TIP
Relay Output can be used to trigger an optional strobe as shown. Another
application for this output would be a door control system.
Refer to the IA500 programming manual for options.
See Relay Ratings
Below
INFO
SPKR
HELP
32 Ohm
Optional
12V DC
Power Supply
(Supplied by Others)
GRD
NEUTRAL
LOAD
Always use a
phone line surge
suppressor for
protection.
28 – 50 mA Loop Current required
To analog telephone service
If loop current is found to be less
than ideal, use either a Ring Voltage
Booster or a Long Loop Adaptor
Ref: Proctor 46222
Optional Strobe
40197
12V DC @ 180ma
Product wiring diagram reasonably represents current offering and is intended to assist in component identication and service. Earlier product production may have different
components and wiring connections. Reference the model and serial number from the unit ID tag and contact manufacturer to conrm replacement part version and availability.
CONTRACT FORM 2 FORM C
Contract Rating
Maximum Switching Power 30W (resistive) 62.5 VA (resistive)
Maximum Switching Voltage 220V DC 250V AC
Maximum Switching Current 1A
Maximum Carrying Current 2A (@20
0
C)
RELAY RATINGS