IA500
Administrator Guide
3 Getting Started
1. The analog phone line will terminate on the barrier strip at Tip and Ring positions.
a. Talk voltage: 24~48
b. Loop Current Range: 27~50mA
2. Relay: The phone has one relay that can be a straight contact closure or supply low
current through the relay to power a remote strobe.
a. Spec Rating: 1A @ 220V DC or 250V AC (EA2-3TNU.1)
The IA500 series phones are remotely programmed. This enables the installer or end user to pro-
gram the unit from a phone on site or from a remote location.
3.1 Construction
Surface Mount
The IA500 housing shall be constructed of 16 gauge stainless steel and measure 7.375” W x 7.125”
H x 2” D and weigh approximately 5 lbs. The housing shall consist of two pieces, permitting the
backplate to be mounted during the rough in and the faceplate installed during completion. The back
shall have four holes for mounting hardware.
Flush Mount
The IA501 faceplate shall be constructed of 12 gauge stainless steel and the ush mounting box of
14 gauge painted steel. It shall measure 9” H x 9” W x 3.5” D and weigh approximately 9 lbs. The
faceplate shall provide an overlap to the mounting box to eliminate additional trim work.