Programming Commands (continued)
Command Explanation Format Default
76 Upon call in answer mode 76<answer mode># 0#
NOTES: FORMAT VALUE PARAMETERS
Command 76 = Answer mode: 0 or 1
0 = automatically enters two-way audio mode without password
1 = requires audio call password or phone will disconnect
Command Explanation Format Default
77 PAS enable
77<pas>Ý<output(s)>Ý<recordings(s)># 0ÝÝ#
78 Enable UPD on call answer 78<upd># 0#
NOTES: FORMAT VALUE PARAMETERS
Command 77 = Public Address System
First Value Set, enabling PAS: 0 or 1
0 = disabled
1 = enabled
Second Value Set (outputs)
See Programming Outputs (page 10)
Third Value Set (recordings)
See Programming Messages (page 11)
Command 78 = Enable Unit Programming & Diagnostics (UPD): 0 or 1
0 = don’t send bit fault on answer menu instead of RFA
1 = send bit fault on answer menu instead of RFA
Pass Codes and Reset Programming
Command Explanation Format Default
90 Programming password
90<new pass code>Ý<new pass code>#
2583#
92 Audio call password
92<new pass code>Ý<new pass code>#
#
95 Reset audio settings
95Ý95#
96 Reset phone numbers only
96Ý96#
97 Reset recordings only
97Ý97#
98 Default all settings EXCEPT
audio, phone and recordings
98Ý98#